User's Manual

Table Of Contents
WavePoint™ Product Safety
Screw Torque
For all connections, use these tightening torque minimum and maximum:
l Minimum: 0.22 Nm.
l Maximum: 0.25 Nm.
WavePoint Conditions of Safe Use
l Provision shall be made to prevent the rated voltage from being exceeded by the transient
disturbances of more than 140% of the peak rated voltage.
l The WavePoint shall be mounted in an ATEX certified enclosure with a minimum
IP54 ingress protection rating (as defined in EN-60529).
l The WavePoint cannot be used in an environment greater than pollution degree 2.
Standards and Editions
l EN 60079-0:2012+A11:2013
l EN 60079-15:2010
l IEC 60079-0, 6th Edition
l IEC 60079-15, 4th Edition