User's Manual
Table Of Contents
- WavePoint™ Product Safety
- Preface
- Chapter 1: Introduction
- Key Features and Supported Protocols
- Requirements
- Accessories
- Product Variations
- WavePoint 10e Labels
- WavePoint™ Components
- Certified Antennas
- Connect Power
- Network Deployment Scenarios
- Connecting and Logging In
- Configuration Pages
- Chapter 2: Configuring Basic WavePoint™ Network Features
- Chapter 3: Additional Data Networking Features
- Chapter 4: Configuring Wireless Access
- Example: Point-to-Point Configuration
- Point-to-Multipoint Configuration Examples
- Configuring Wireless Communication
- Defining Advanced Radio Settings
- Verify the Wireless Connection
- Enabling Virtual Access Points
- Wireless Security
- Scheduling When Wireless Connections are Available
- Chapter 5: Security
- Chapter 6: Management and Administration
- Set Up Remote Access to the WAN Port
- User Access Management
- Software Maintenance
- System Logging
- Simple Network Management Protocol (SNMP)
- Authentication Certificates
- Setting the Date and Time
- System Statistics
- Chapter 7: Diagnostics and Troubleshooting
- Appendix A: Factory Default Settings
- Chapter B: Installation Instructions
- Appendix C: WavePoint™ Configurations
- Appendix D: Bench Test Verification of WavePoint™ Configuration
- Appendix E: WavePoint 10e Technical Specifications
- Glossary
- Index
Chapter 1: Introduction
c. The antennas used for the WavePoint™ must be fixed-mounted on outdoor
permanent structures to provide the minimum separation distances described in this
filing for satisfying RF exposure compliance requirements.
d. When applicable, RF exposure compliance may need to be addressed at the time of
licensing, as required by the responsible FCC Bureaus, including antenna co-location
requirements of §1.1307(b)(3).
2. Typically, the antenna connected to the transmitter is a directional (high gain) antenna,
fixed-mounted on the side or top of a building, or on a tower.
a. Depending upon the application and the gain of the antenna, the total composite power
could exceed 20 watts EIRP.
b. The antenna location must only be accessible by qualified technical personnel.
c. Under normal operating conditions, no other person can touch the antenna or
approach within 3.05 meters of the antenna.
Note: These antennas have been approved for use with WavePoint 10e and the
designated Tx Streams.
900MHz Antennas
Note: Separation minimum RF safety distances are required for FCC RF exposure
compliance.
900 MHz Antennas
Type Antenna Model Gain
No of
Tx Streams
Channel
Size
Minimum RF
Safety Distance
Omni Wavelink - PRO902-11 11dBi 2 20 MHz 94cm
Yagi Wavelink - PRO890-16 16dBi 2 20 MHz 260cm
2.4GHz Antennas
Note: Separation minimum RF safety distances are required for FCC RF exposure
compliance.
2.4GHz Antennas
Type Antenna Model Gain
No of
Tx Streams
Channel
Size
Minimum RF
Safety Distance
Dipole 98618MNXX001 5dBi 3 20 MHz 20cm
Page 24 of 171 LUM0063AA Rev 05/05/2014
This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by
FreeWave®. This document cannot be reproduced in whole or in part by any means without written permission from