User's Manual

FreeWave Technologies Spread Spectrum Transceiver User Manual
900 MHz and 2.4 GHz
V5.0S
22
The Baud Rate section of the user interface provides two other important
parameters, the ability to change the transceiver's word length and to put it into
ModBus RTU mode.
(2) Data Word Length and Parity
There are six data word length and parity configurations available to be used with
FreeWave transceivers. The default setting is 0 (8,N,1) and is the most commonly
used serial communications protocol.
Data word length and parity selections available:
(3) ModBus RTU
Support for ModBus RTU protocol is available. The default setting for ModBus
RTU is 0 (not enabled).
To enable the ModBus RTU mode:
1. In the Set Baud Rate menu enter (B) and then select 1
2. In the Set MultiPoint Parameters menu, set Master Packet Repeat to 3.
Note: When using the transceivers in ModBus RTU mode the Master Packet
Repeat must be set to 3 regardless of whether the transceivers are being
used in Point to Point or Multipoint mode.
Note: The ModBus RTU mode must be selected in RS485 modems.
RS232/485
In products for which the protocol of the Data port is software selectable (such as
FGR09xx, FGR-115RC, FGR115W), use this menu to set the protocol of its data
Table 4: Data Word Length
and Parity
Selections
Menu
Setting
Data Bits Parity Stop Bits
0 8 None 1
1 7 Even 1
2 7 Odd 1
3 8 None 2
4 8 Even 1
5 8 Odd 1