User's Manual
Table Of Contents
- FreeWave Technologies
- LRS-455-EU
- Data Transceiver
- Version 1.0, Revision A
- About FreeWave Transceivers
- Choosing a Location for the Transceivers
- Quick Start on a Point-to-Point Network
- Setting up a Transceiver
- Operation Mode
- Baud Rate
- Modbus RTU Timing
- The Modbus RTU setting causes the radio to wait for an amount of time, “gathering” data before sending out the radio link.
- With a setting of 0 (Disabled), the radio will send data out its radio link as soon as the data is received into the serial port.
- With a setting of 1, the radio will wait for a number of slots equal to 2 times the Master Packet Repeat setting before sending the received data out the radio link. For example, if Master Packet Repeat = 3, the radio will wait for 6 slots, gathering ...
- With a setting of 2 and higher, the radio will wait for a number of slots calculated by the following formula:
- (Modbus RTU Setting + Master Packet Repeat Setting + 1) x 2
- For example, in a radio where the Modbus RTU setting = 2 and the Master Packet Repeat setting = 3, the radio will wait for (2+3+1) x 2, or 12 slots.
- Call Book
- Radio Transmission Characteristics
- Edit Radio Transmission Characteristics
- MultiPoint Parameters
- Edit MultiPoint Parameters
- Radio Information
- Operational RS-422 and RS-485 Information
- RS232 Pin Assignments
- RF Board Pinout
- FreeWave Technical Support
- Errata
LRS-455-EU Data Transceiver Users Manual
LUM0032AA Rev A Version 1.0 iv
ETSI NOTIFICATIONS
LRS-455-EU series radios have been certified to the following ETSI standards:
ETSI EN 300 113-1:2009
ETSI EN 300 113-2:2009
ETSI EN 301 489-1:2008
EN 61000-4-2: 1995 With A1:1998 and A2:2001
EN 61000-4-3: 2006
EN 61000-4-4: 2004
EN 61000-4-6: 1995 With A1:2004 and A2:2006
EN55022: 2006
ISO 7637-2: 2004