User's Manual
Table Of Contents
- FreeWave Technologies
- LRS-455-EU
- Data Transceiver
- Version 1.0, Revision A
- About FreeWave Transceivers
- Choosing a Location for the Transceivers
- Quick Start on a Point-to-Point Network
- Setting up a Transceiver
- Operation Mode
- Baud Rate
- Modbus RTU Timing
- The Modbus RTU setting causes the radio to wait for an amount of time, “gathering” data before sending out the radio link.
- With a setting of 0 (Disabled), the radio will send data out its radio link as soon as the data is received into the serial port.
- With a setting of 1, the radio will wait for a number of slots equal to 2 times the Master Packet Repeat setting before sending the received data out the radio link. For example, if Master Packet Repeat = 3, the radio will wait for 6 slots, gathering ...
- With a setting of 2 and higher, the radio will wait for a number of slots calculated by the following formula:
- (Modbus RTU Setting + Master Packet Repeat Setting + 1) x 2
- For example, in a radio where the Modbus RTU setting = 2 and the Master Packet Repeat setting = 3, the radio will wait for (2+3+1) x 2, or 12 slots.
- Call Book
- Radio Transmission Characteristics
- Edit Radio Transmission Characteristics
- MultiPoint Parameters
- Edit MultiPoint Parameters
- Radio Information
- Operational RS-422 and RS-485 Information
- RS232 Pin Assignments
- RF Board Pinout
- FreeWave Technical Support
- Errata
LRS-455-EU Data Transceiver Users Manual
LUM0032AA Rev A Version 1.0 7
Baud Rate
This setting is the communication rate between the transceiver and the instrument to which it is
connected. It is important to note that this is independent of the baud rate for the other transceiver(s) in
the network. For example, a pair of transceivers may be used in an application to send data from remote
process instrumentation to an engineer's computer. In this application, the baud rate for the transceiver
on the instrumentation might be set to 9600, and the transceiver on the engineer’s computer might be set
to 57,600.
Set Baud Rate
1. Select the appropriate baud rate to match the attached device.