ValueLoader LTO Tape Autoloader User Manual 61
3090 Mechanical Initialization
Failure.
The robotics were not able to move to the safe
mechanical initialization position. Manual
intervention is necessary.
3091 Inventory Scan Failure. Fatal robotic error occurred during the
inventory scan.
3092 Preposition Failed. Belt positioning error occurred during
‘Preposition’ command.
3093 Cartridge Load Error. A failure occurred while trying to load a
cartridge from a slot to the drive.
3094 Cartridge Unload Error. A failure occurred while trying to unload a
cartridge from the drive to its slot.
3095 Import Error. An error occurred while trying to import a data
cartridge to a carousel slot.
3096 Export Error. An error occurred while trying to export a data
cartridge from its carousel slot. This can be
caused by an empty slot that is expected to be
full.
30A0 Carousel Motion Failure. An error occurred during carousel movement
(position not found). This could be caused by a
missing or misaligned cartridge carrier, an
obstruction, or an unexpected cartridge in
either the carousel path or the import/export
slot.
30A1 Cartridge Transport Position
Error.
The cartridge transport element is unable to
reach its desired position. Failure occurred
while trying to place a cartridge into or remove
a cartridge from the drive or a slot.
30A2 Gripper Position Error. Gripper unable to reach position.
30A3 Cartridge Pick Error. An error occurred while trying to pull a
cartridge from the drive or a carousel slot.
Error Code Description Details