® Models RCS-S3000T RCS-S5000U RCS-S5000B PORTABLE AIR CONDITIONER OPERATION MANUAL IMPORTANT NOTICE: To avoid damage and voiding your warranty, place both units in their upright positions for a minimum of two hours before operating. For best results, and more enjoyment from your new FREECOM portable air conditioning unit, please read this instruction manual carefully and save for future reference.
TABLE OF CONTENTS Owner's Record ............................................................................................................2 Features ........................................................................................................................3 Specifications ................................................................................................................3 Hardware (Included) .........................................................................................
FEATURES Thank you for purchasing the FREECOM RCS-S3000T Portable Air Conditioner. The RCS-S3000 and RCS-S5000 series Portable Air Conditioners are designed with many state-of-the art features: • Wireless remote control enables operation of up to 16 feet (5 meters) from indoor unit. • Quiet, durable caster wheels allow for easy movement of indoor unit. • Efficient "split" design for maximum cooling and easy installation. • Convenient, electronic operation panel enables one-touch control of all functions.
TRES IMPORTANT Pour éviter les risques d'incendie ou de choc électrique, n'exposez pas l'appareil à la pluie ou à l'humidité. En cas de panne, faites appel au service après-vente qualifié pour effectuer des réparations sur cet appareil. Votre climatiseur contient un réfrigérant qui passe d'une phase gazeuse à une phase liquide au moyen d'un compresseur. Il doit être utilisé en position verticale.
IMPORTANT SAFETY INFORMATION PLEASE READ AND FOLLOW ALL SAFETY INFORMATION AND INSTRUCTIONS BEFORE OPERATING YOUR NEW FREECOM AIR CONDITIONER. WARNING: ELECTRICAL SHOCK HAZARD. Failure to follow the safety information below can result in severe personal injury or property damage. • • • • • • • • Use this product only with the proper electrical voltage. (See “Specifications.”) DO NOT use the electrical plug to start or stop the unit.
PRODUCT PARTS C A F D B E A L FRONT VIEW G Q P B M N K A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q.
THE CONTROL PANEL 4 3 10 11 9 8 7 6 5 2 1 1. POWER ON/OFF "I/O" Easy push-button control switch to turn the unit ON and OFF. 2. MODE There are five different fan speed settings: • AUTO—Automatic fan speed with cooling setting by room temperature. • HI—High fan speed with cooling setting • MED—Medium fan speed with cooling setting • LO—Low fan speed with cooling setting. • FAN—Fan only (no cooling) 3. MODE LEDs Individual LED lights to show mode in operation. 4.
BEFORE USING IMPORTANT: Remove unit from packaging and discard clear, plastic wrapping. Place both units in upright position for a minimum of two hours before operating for the first time. CAUTION: Never use line/tube set to move, carry, or lift units. DO NOT place units near open flame or heat source. INSTALLATION Indoor Unit 1. Place indoor unit on a solid, level surface. Operating this unit on uneven or soft surfaces may cause vibration, noise, and possible water leakage. 2.
INSTALLATION (contd.) Outdoor Unit The outdoor unit can be either surface placed or wall-mounted. In either case, the outdoor unit must be fitted so the flexible tube set easily reaches the indoor unit. The flexible tube set can be routed through a window, door, or wall. For routing through a wall, please consult a certified contractor to perform interior and exterior hole cutting and disconnecting the tube set. 1. Determine an exterior position for outdoor unit.
INSTALLATION (contd.) Wall-Mounting (contd.) CAUTION: Always wear eye protection (safety goggles) when drilling. 5. Using a drill bit (masonry drill bit for concrete), drill mounting hole locations. Mount brackets to exterior wall with supplied 1/4" anchors(4) and 1/4" screws (4). 6. Check that brackets are secure on wall. 7. Use handle to carefully lift outdoor unit onto mounting brackets. The top tabs on the mounting bracket will fit into the bottom metal brackets on the back of the unit.
OPERATION CAUTION: To avoid damage and voiding your warranty, place both units in their upright positions for a minimum of two hours before operating. DO NOT operate unit without air filter properly in place or while tube set is disconnected. Cooling This unit is intended to cool a 300-600 square foot area. The unit’s cooling capacity will vary according to room temperature and humidity. Consult your Freecom dealer for specific application and suitability. 1.
OPERATION (contd.) Operating the Timer If you wish to check the timer setting after the timer has been programmed, press the "TIMER-SET" button on control panel while timer "ON" or "OFF" light is on. The display will show the hours remaining until the timer function is operating. Pressing "TIMERSET" again will increase timer setting. To Turn Unit On with Timer 1. While the unit is off, press “TIMER-SET” button on control panel to program the air conditioning unit to turn on in 1-24 hours.
MAINTENANCE AND CLEANING Draining Water Tank When the condensate water tank is full, the “DRAIN WATER” indicator light will flash, the unit will sound several initial warning beeps, and the unit will automatically turn off. IMPORTANT: For the indoor unit's condensate drain pump to function properly, the outdoor unit must not be more than 6 feet above indoor unit. NOTE: If emptying water tank before “DRAIN WATER” alert, press Power On/Off "I/O" button to stop unit if it is operating. 1.
MAINTENANCE AND CLEANING (contd.) Cleaning Air Filter This unit has one air filter. For best results and maximum performance, clean filter every two weeks, or as required by environmental conditions. CAUTION: Neglect or failure to regularly clean the filter will result in poor efficiency, reduced performance, possible damage to the unit, and voiding your warranty. 1. Press Power On/Off "I/O" button to stop unit if it is operating. Unplug power cord from outlet. 2.
MAINTENANCE AND CLEANING (contd.) Cleaning Cabinet Exterior WARNING: ELECTRICAL SHOCK HAZARD: • • • • • Never operate or (un)plug unit with wet hands. Turn off unit and unplug from wall outlet before cleaning. Never submerse the unit in any type of liquid or expose to heavy moisture. Never spray, pour, or sponge water directly onto the unit . Never use brushes, brooms, harsh detergents, chemicals, solvents, gasoline, or any other abrasive materials or household items to clean the unit.
TROUBLESHOOTING Before contacting a dealer or qualified service technician, please read and check the following troubleshooting guide. If, after reviewing and performing the following solutions, your unit should continue to operate improperly, turn unit off and contact your Freecom dealer for service. CAUTION: Always use a qualified electrician to check/repair electrical systems. PROBLEM SOLUTION Unit does not turn on. 1. 2. 3. 4. 5. 6. 7. Unit running low air flow or cooling. 1. 2. 3. 4.