5.1.1.2. Sealer Maintenance
From time to time, the letter sealer must be cleaned
or wearing parts replaced. To this end, press the
“Sealer Maintenance” key.
After the cleaning operation, press the “Restart”
key.
The letter sealer is beneath the water tank.
Caution! Always use the menu item “Sealer
Maintenance” to remove the letter sealer. Be
careful with the water bottle in order to keep
the environment in a dry shape.
If you don’t, you might damage the letter sealer mechanism.
This is how you clean the letter sealer:
Press the key “Clean letter sealer”. Don’t switch off the feeder AFS6.
Remove the water tank.
Localize the letter sealer. Grip the letter sealer at the side and pull it out of
the feeder AFS6.
Hold the letter sealer firmly in one hand and remove the wick moistener.
Clean or replace the moistener. Put the moistener back in place, fit the
letter sealer in the AFS6, top up the tank with distilled water and put back
the tank.
Press the “Restart” key.