Operation Manual

Frama Matrix F12
26
Unpack the new ink jet cassette and remove the two protective strips from the print
head.
On the top of the ink jet cassette you will find two grip surfaces. Press them to-
gether between your thumb and forefinger.
Insert the ink jet cassette from above. Follow the contour of the cover as you do
this.
Push the new ink jet cassette fully into its guide.
Release the grip surfaces. Push the ink jet cassette back with one finger to make
sure that the locking tabs are correctly positioned and that the ink jet cassette is
locked into place.
Information
The locking tabs must engage at the side (see photograph). Check that the ink jet cassette is prop-
erly seated before you close the cover again. The cover must close easily without the need for force.
If you have fitted the new cassette properly, you can now press YES
on
the screen.
The ink jet cassette will now be tested and calibrated. This process might take a few seconds.
If the ink jet cassette being used has already been fitted in your Frama Matrix F12 franking system, you
can choose between recalibration and accepting the existing calibration data. Calibrate, are you sure?
After calibration, you will be prompted to print a test frank-
ing mark. Take an envelope. We recommend that you use a
filled envelope.
Insert the envelope as for franking. The envelope will be
franked with a test mark and ejected to the left.