Palapala a ka mea nona

Analogue Productions Test LP tracks:
Track 1: 1 kHz sine wave, Both left and right channels
Track 2: 1 kHz sine wave, Left channel only
Track 3: 1 kHz sine wave, Right channel only
Mechanical Meter Check
Check your FOZGOMETER
V2 with the power both off and
on to verify that the meter
reads 0. See figure 1. To
adjust, power on and turn the
black meter trim screw located
at the lower middle of the
meter until the needle points
closest to ZERO.
Patience is a Virtue:
Given the small profile of
modern styli, adjusting
azimuth may require many
small adjustments.
Figure 1, Meter 0
Azimuth Measurement Procedure:
Lower your phono cartridge on the stationary Test LP.
Visually examine cartridge lowered on test record,
viewing from the front. Adjust tonearm headshell
so top of cartridge is parallel to record surface. You will
use this physical adjustment of your tonearm headshell
later to fine tune azimuth. Cue up your tonearm.
Channel Balance:
Turn on your turntable to 33.3 RPM and play Track 1 on
the Test LP. If the channels are balanced, the meter will
read near zero and only the CENTER light will illuminate.
See figure 2.