Product Manual

CO7338.1 7 IN20525 Rev D 3/30/2009
T7
T1
T8
T2
T9T3
T4
T5
T6
L1
L2
L3
T7 T4
T1L1
T8 T5
T2
L2
T9 T6T3
L3
T1
T2
T3
U2
V2
W2
W1
V1
U1
208-240V
50/60Hz. 3Ø
440-480V 50/60 Hz. 3Ø
380-400V 50 Hz. 3Ø
575V 60 Hz. 3Ø
(4) M5 x 45 PHMS, Plated
(4) M5 x 10 PHMS, Plated
Capacitor BoxTo Power Unit
Drum Switch
And Cover
Re-seal Between
Box And Spacer
With Silicone
Sealer
Capacitor
Box
Gasket
Steel Spacer
Capacitor Box Attachment
Option Two
L1
PE
L2
L3
MOTOR
1
3
5
2
4
6
DRUM
SWITCH
3 Phase
Supply
Capacitor Box Attachment
Option One
L1
PE
L2
L3
MOTOR
1
5
7
2
6
8
DRUM
SWITCH
3 Phase
Supply
FOR 3 Ø POWER
UNITS: Attach Box using
M5 x 10 PHMS, Plated
NOTES:
1. Unit not suitable for use in unusual conditions. Contact
Rotary for moisture and dust environment duty unit.
2.
3. Motor rotation is counter clockwise from top of motor.
NOTE: Two Different Drum Switches were used
please select one of the two options below.
Three Phase Power Unit
MOTOR OPERATING DATA TABLE - THREE PHASE
LINE VOLTAGE RUNNING MOTOR VOLTAGE RANGE
208-240V 50/60Hz. 197-253V
400V 50Hz. 360-440V
440-480V 50/60Hz. 396V-528V
575V 60Hz. 518V-632V
FIGURE B