Product Manual
9000 lbs. Floor Plate Lift IN60001 Rev. C 11/6/2008
13
STEP 17
: Remove the vented fill cap from the power unit and fill the reservoir. Use a Ten
Weight (ISO AW32) non-foaming, non-detergent hydraulic fluid (i.e. Texaco HD32 or equal).
The unit will hold approximately twelve quarts of fluid. If a replacement fill cap is required order
from your distributor, a vented cap MUST be used.
STEP 18:
Electrical:
Have a certified electrician run appropriate power supply to motor, Fig.
A & B. Size wire for 20 amp circuit. See Motor Operating Data Table.
Never operate the motor on line voltage less than 208V. Motor damage may
occur.
Important:
Use separate circuit for each power unit. Protect each circuit with time delay fuse
or circuit breaker. For single phase 208-230V, use 20 amp fuse.Three phase 208-240V, use 20
amp fuse, For three phase 400V
(*E Model)
and above, use 10 amp fuse.. For wiring see Fig.
A & Fig. B. All wiring must comply with NEC and all local electrical codes.
Note:
60Hz. single phase motor
CAN NOT
be run on 50Hz. line without a physical change in
the motor.