Instructions / Assembly
PART 3 EXECUTION
3.01 PREPARATION
Stake layout showing locations of all gates and posts. Contact “CALL BEFORE YOU DIG” prior to beginning any excavation
work.
3.02 INSTALLATION
A. Install fences in accordance with written instructions and in accordance with authorities having jurisdiction.
B. Concrete Set Posts: Drill hole in firm soil. Posts holes will be a minimum of 24” deep (environmental conditions or local
codes may require a greater depth). Fence post shall be spaced according to on-center chart to accommodate installation of
brackets on 2” square post. For non-level installations the on-center post spacing must be measured along the grade.
C. Installation is to conform to the specifications referenced in Section 1.02 of this specification.
D. Install Fortress brackets onto fence section and posts as indicated in printed instructions for specific fence style. Attach
fence sections to brackets with approved fasteners and techniques to insure that fence sections are parallel to grade within ¼”
in 12 feet.
E. Gate Installation: Install in accordance with printed instructions. Do not mount gate from wall of a structure. Provide gate
post on both sides of a gate. For double drive gate installation, provide concrete center drop to foundation depth and drop rod
retainers at center. Lubricate to insure smooth operation and verify proper latch operation.
3.03 CLEANING
A. Remove all cutting and drilling chips that are attached to the fencing, post, brackets or additions to prevent corrosion.
B. Repair scratches and other installation-incurred damage. Using a spray paint of the appropriate color that includes a zinc
additive, repaint and seal any scratches or holes drilled in the fencing, post, brackets, or additions to prevent rust from forming.
C. Clean up debris and unused material, and remove from site.
Table 1
Minimum Post Sizes for Versai Residential
Line of Fence Posts
Panel Heights
2” x 16 Ga.
Up to & Including 6’ height
Table 2
Versai Residential Post Spacing by Bracket Type
Style
Flat Top Flat Bottom, Flat Top, Pressed Spear, Extended Picket
Post Size
2”
2”
2”
2”
2”
Bracket Type
Omni-104
One Direction
Flat Mount
(EX-104)
Two Direction
Line
(EXW-104)
Three Direction
Universal
(EXW-304)
Swivel
Flat Mount
(EXS-104)
Post Setting
93.5” + ½”
93.5” + ½”
93.25” + ½”
93.25” + ½”
94.75” + ½”
Style
Flat Top Flat Bottom, Flat Top, Pressed Spear, Extended Picket
Post Size
2”
2”
2”
Bracket Type
One Direction
Flat Mount
(EX-104 96” OC)
Two Direction
Line
(EXW-104 96” OC)
Three Direction
Universal
(EXW-304 96” OC)
Post Setting
95.25” + ½”
95.25” + ½”
95.25” + ½”
Table 3
Versai Residential Gate Posts Sizes
Gate Leaf
Gate Height
Up to & Including 6’
Up to 5’
2” x 16 Ga.
6’ to 8’
2.5” x 16 Ga.