User Guide

ES210 Hardware Guide: LEDs and Pushbutton Operation
15
3.2 Pushbutton Operation
The ES210 Bridge is equipped with three push buttons.
Figure 3.2. ES210 Push Buttons
NOTE: If the
Bridge’s internal
temperature reaches
176ºF (80ºC) it powers
itself off. If you power it
up before the Bridge has
cooled, it will again
shutdown.
3.2.1 Powering the Bridge On and Off
When the ES210 Bridge is powered off, the lower button on the
left side of the chassis powers it on. The single button on the
right side of the chassis powers it off.
If the Bridge is off, press and hold the Power On button for
five seconds to turn it on.
The
Power LED will slow-flash green while the Bridge
boots, then light solid green for normal operation.
NOTE: If the
Bridge is running
and the
Power On but-
ton is pushed and held,
it toggles
Blackout Mode
so the Bridge appears to
be powered off. If the
unit has batteries, this
condition will drain the
batteries.
or
If the Bridge is on, press the Power Off button to turn it off.
The
Power LED will go dark.
3.2.1.1 Pushbutton Rebooting
Reboot (hard boot) the ES210 by powering it off and back on
again (described above).
3.2.2 Pushbutton Blackout Mode Operation
When the ES210 Bridge is powered on, the lower button on the
left side of the chassis turns the Bridge’s top-panel LEDs off
and on (
Blackout Mode, Enabled/Disabled).
The default blackout mode setting is
Disabled, in which state
the Bridge’s top-panel LEDs illuminate to indicate various
conditions. (LED behaviors and their associated meanings are
covered in Section 3.1.) Enabling blackout mode turns all top-
panel LEDs off.
rightleft
RF Kill
Power On/
Blackout Mode
Power Off