Sol-Ark Integration Guide
 Rev 2.1 09-14-21 
Fortress Power - Sol-Ark Inverter Guide 
505 Keystone Rd, Southampton, PA 18966 . (877) 497 6937. sales@fortresspower.com . Fortresspower.com 
Step 3 – Install the battery-to-battery communication circuit 
When installing multiple batteries, it is necessary to use the canbus terminators. This procedure is 
different for the eFlex, eVault MAX, and eVault Classic. 
eFlex and eVault Classic: 
It does not matter which communication port 
you plug into on the eVault or eFlex – they are 
universal. The canbus terminator looks like a 
standard ethernet plug without a cable 
attached. 
The eFlex uses an RJ45 pinout connector 
between the eFlex battery and the battery 
inverter. 
The eVault Classic does not use RJ45 pinout 
converter and can only parallel up to 2 eVaults 
when communicating to the inverter. 
If not communicating to the inverter, put a 
canbus terminator plug on each end of the 
communication circuit. 
 See product manuals for additional detail. 
eVault MAX: 
The eVault MAX has the canbus terminators 
built into the unit. The two eVault MAX units on 
the end have the canbus terminators set to ON.  
It is does not mattery if the canbus terminator 
to ON or OFF when installing one eVault MAX. 
The eVault MAX has dedicated a dedicated 
port for inverter communication. For the 
Sol-Ark inverter, use the RS485 port of the 
master eVault MAX. 