OutBack Integration Guide
Rev1.6_01-22-22 
Set Up Fortress Power Lithium Batteries with Outback Systems 
505 Keystone Rd, Southampton, PA 18966 . (877) 497 6937. sales@fortresspower.com . Fortresspower.com 
2 
SkyBox Inverter Settings 
The settings below should be programmed into the unit under the Custom choice. 
Inverter 
Maximum SOC 
100% 
Minimum SOC 
20% 
Absorb Charge 
Timed 
Absorb Voltage 
55.2 Vdc 
Absorb Time 
02:00 hr 
Float Charge 
Disabled 
Float Voltage 
Can be left at default 
Float Time 
 Can be left at default 
Re-float Voltage 
54.4 Vdc 
Re-bulk Voltage 
52.5 Vdc 
Equalize Voltage 
54.4 Vdc 
Minimum Equalize Time 
00:00 
Max Charge Current (Adc) 
LFP-5 & LFP-10: 50Adc 
eVault: 100Adc 
eFlex: 60Adc 
Max Discharge Current 
(Adc) 
LFP-5 & LFP-10: 90Adc 
eVault: 125Adc 
eFlex: 60Adc 
Grid Charge Limit (kW) 
Site specific 
Low Battery Cutout 
50 Vdc 
LBCO Delay 
130 seconds 
Low Battery Restart 
51.2 Vdc 
High Battery Cutout 
56.0 Vdc 
HBCO Delay 
10 seconds 
High Battery Cut-in 
55.5 Vdc 
Battery Series 
Custom 
Battery Model Number 
Custom 
Battery Description 
Fortress Power 
Battery Total Amp-Hours 
eFlex: 105Ah 
LFPP-10: 200Ah 
eVault: 360 Ah 
Charge Efficiency Factor 
96% 
Absorb End Amps 
1Adc 