Victron Integration Guide
Rev 2.1 09-14-21
7
Fortress Power - Victron Inverter Guide
eVault MAX:
Modified Battery-to-Inverter Communication cable
eVault Inverter CAN port pins 1+2 correspond to Victron
pins 7+8.
cut a standard ethernet cable,
cut out wires 3+4+5+6+7+8
cross wires connecting 1+2 on the eFlex to 7+8 in the
Victron VE.Can port.
Note: nothing is connected to eVault Inverter RS485 port
The eVault MAX has dedicated a dedicated port for
inverter communication.
Connect the modified communication cable from the
eVault Max Inverter CAN port to VE.CAN
If more than one eVault is being used the modified Inverter cable connects to eVault Battery number 1
eVault MAX COMMUNICATION PROTCOL
eVault MAX VE.CAN Bus protocol is used with the unique setting of 4
Protool ID is set to 4 for Victron GX using the front panel
touchscreen.