between master and slave modes until it clicks on, and then leave in the appropriate
master or slave mode. After the battery unsticks, power down and then power back up
the battery banks using the push button if convenient.
Battery-Inverter Connection
.
***Closed loop is only compatible for up to 1 battery. Make sure that each battery is updated to firmware version
7.7.Important! Place the terminator in one of the communication ports (Both TX and RX are common ports) and
the communication cable in the other. Set Battery to Master 1
1. To pair both batteries, turn them on pressing the push-button for about 10 seconds and set both batteries to
Slave with Parallel Number 2. Turn them off. While batteries are off, connect the communication cables from
one battery to another (RS485 ports are common) and end communication with a terminator to the battery that
you will choose to be the Slave.
2.
Turn Both batteries on. Set one of the batteries to Master.. If paralleling is successful, you should hear a
clicking sound on both batteries after this step.
Note: The Master battery will communicate directly with the inverter Insert the remaining Format B Ethernet cable from the
Master battery to the Gateway/Insight Home/Insight Facility.
Battery/Inverter Integration