kWh Lithium Ferro Phosphate (LFP) Installation

Rev. 1.8
505 Keystone Rd, Southampton, PA 18966, USA . (877) 497 6937. sales@fortresspower.com .
www.fortresspower.com
26
5.3 Parameter set up guide for Charger/Inverter
Before commissioning the energy storage system, the appropriate controller and inverter settings
must be programmed per the manufacturer’s recommendations. Consult the manufacturer’s
manuals and/or access technical support (Darfon, Schneider, Outback, SMA, Sol-Ark, Magnum,
Outback).
Although Fortress Lithium batteries can perform at very high rates and depths of discharge within
a very wide temperature range, in order to achieve extended life cycles and to comply with the
Warranty, the following guidelines should be followed:
Understanding Charge Stage
1. Bulk Charge: Charge at Constant
Current (CC) to Bulk/Absorb Voltage
2. Absorption Charge: Maintain
Constant Bulk/Absorb Voltage (CV)
3. Terminate when charge current
drops below 0.05C
4. Unlike Lead Acid batteries, Lithium
Ferro Phosphate batteries do not
require Float Charge
Charger/Inverter configuration recommendation for best Performance:
The Battery Parameter Setting Guides with SMA, Sol-Ark, Schneider and Outback
Inverters/Chargers are available to download on www.fortresspower.com/Resource
Recommended operating parameters of charger/Inverters For 3,000 Cycles:
Operating temperature range: 32 F to 120 F (0 °C to 49°C)
Bulk voltage and absorb voltage should be set to 54.4V
Recommended operating parameters of charger/Inverters For 6,000 Cycles:
Operating temperature range: 50 F to 110 F (10°C to 43°C)
Storage must be equal to or more than twice the rated output of the Inverter
Bulk voltage and absorb voltage should be set to 54.4V
At the End of Cycle Life capacity is Equivalent to 70% Retained Capacity
CAUTION! Do Not Operate Fortress Lithium Batteries at an average temperature
exceeding 30 °C / 86 °F over the life of the battery.