Installation Manual

PREPARE HOT WATER LINE AND
POWER CORD HOLE
Water Line Connection
The line may enter from either side, rear or floor within the shaded
area shown in Figure F.
Each cut an additional 1-4/5” dia. hole to accommodate the water
line and the power cord.
Figure F
Shut-off
Valve
1-4/5" Dia.
Hole
1-4/5" Dia.
Hole
Hot
Cabinet Face
A
B
Turn off the water supply.
Install a hand shut-off valve in an accessible location, such
as under the sink. (Optional, but strongly recommended
and may be required by local codes.)
Connect one end of inlet line(A) to the 3/4-inch FHT(B) and
connect to the dishwasher.
Run the other end of the inlet line through the hole in the
cabinet. If the shut-off valve is 3/8 inch I.D., the inlet line
can be directly connected to the shut-off valve.
Adjust water heater for 120°F to 150 °F temperature.
Flush water line to clean out debris.
The hot water supply line pressure must be 6-145 PSI.
Opening the door will cause the dishwasher to tip forward. Do
not open the door until you are ready to install the dishwasher.
If it is necessary to open the door, hold the top of the
dishwasher securely with one hand and hold the door with the
other hand.
CAUTION:
8
INSTALLATION PREPARATION
DISHWASHER SETUP