Operational Manual
By wiper through the slot of handle retract right
(curved) end of magazine locking button spring left/up
so, that curved end run out of button deepening, holding
pressed spring, pull out it direct end from button hole,
push out the spring of frame groove, then pull out
magazine locking button from frame hole.
Push out the trigger axis by drift pin and pull
down the trigger so, that its end will enter into hole of
trigger bow, herewith connectivity node of trigger with
rod will be out of frame.
Push out the rod spring axis by drift pin, separate
trigger from rod and rod spring. Pull out trigger and rod
through top slot of the frame .
Push out the firing-pin plug by drift pin at right
or left side of slide. Holding firing pin by hand, get out
drift pin, then separate firing pin and slide, spring and
firing pin.
Knock the extractor pin by drift pin, by holding
the extractor by hand pull the drift pin, get out extractor
and extractor spring.
3.5 Disassembly of the magazine
Before disassembly of the magazine, take out
all cartridges. Press magazine floor plate by the drift pin
and carefully move it forward, holding the bottom of the
magazine. Put out the bottom and magazine spring with
follower.
3.6 Cleaning of the device
Cleaning of the device carry out by special
lubricating oil, cleaning of the bore carry out by special
cleaning fluid in the following order.
12
End of the table 4.1
Name of failure while
shooting
Possible reason
Troubleshooting
method
P inching of the
cartridge between the
face of the slide and
barre l body by
sending the cartridge
to the chamber
1 Magazine pollution
2 Straightening of
magazine lips
3 Magazine is not
fixed by magazine
locking button
1 Pull out the
magazine, take the
slide back, pull out
the pinched
cartridge. Continue
shooting
2 Unload the
device, change the
magazine. Send
the defective
magazine to the
workshop.
3 Pull out the
magazine. Take the
slide back, pull out
the dam aged
cartridge. Insert the
magazine.
Continue shooting
Cartridge-case is
jammed in the bore.
Slide is in backside
position. During shot
there was higher recoil
and intense sound
1 Contamination of
the bore.
2 Cartridge damage
Unload the device
and disassembly it,
push jammed
cartridge by the
wiper towards the
chamber, clean the
bore. Check
disassembled
device: if ejector is
bend, align it; if
extractor is
damage, send
device to the
workshop.
17
- there must be no crack, stratifications, metal
breach on the slide;
- there must be no breaks, especially in the back
part and seat of the hammer, on the frame;
- the firing pin should move freely in the slide
channel;
- there must be no chips on the extractor hook
and hammer head;
- there must be no cracks and layers on the
magazine follower;
- magazine lips must not be deformed;
- all details of device must have no any disunities,
deformations and blight.
3.8 Lubrication and assembly of the device
After cleaning and inspection of the disassembled
device, components and device mechanisms lubricate
by lubricating oil.
Apply a thin coat of oil with a cloth moistened
with oil and squeezed out.
Remove oil flows by dry cloth.
Carry out assembly of the device and magazine
in the reverse sequence as described in section 3.3 "Field
stripping instructions", 3.4 "Disassembly of the device"
and 3.5 "Disassembly of the magazine"
forward position under the action of recoil spring. Insert
the m agazine and check its fixa tion .
Pull out the magazine, set the slide in rearmost
position and release, slide will set in forward position.
Press the trigger. Hammer is cocking and striking
the firing pin.
3.10 Preservation
The manufacturer carries out canning/preserving
of the device. Maximum term of storage of the device
without repeated preservation is no more than one year.
For depreservation of the device it is necessary to carry
out its disassembly and cleaning, in accordance with
section 3 of this manual.
At achieving the maximum term of its storage or
in the case when the device is not used for a long time, it
is necessary to carry out depreservation by using the
method of putting thick layer of lubricating oil on its
internal and external surfaces.
Use the wiper, which is included in the complete
set of supply, square of cloth and lubricating oil during
carrying out of the device preservation and
depreservation.
3.9 Inspection of the device function
Direct device barrel in safe direction without
inserting magazine into handle slot.
Set the slide in rearmost position and inspect
the chamber through the slide slot, it must be empty.
Release the slide, slide should be set in the
14 15