Operational Manual
5 STORAGE OF THE DEVICE
For a long-term storage of the device it is
necessary to carry out its preservation. Procedure for
the carry out preservation is done in the section 3.10 of
this manual. After canning you should wrap up the device
with pa per.
Preserved and packed device must be stored in
the closed storehouses, where temperature and humidity
fluctuation are less than in open air.
Maximum storage term of the canned device is
not more one year from the canning.
6 TRANSPORTATION
The device in the package of the origanal
packing is transported by any transport for any distances:
in the covered railroad car, covered cars, air-tight
apartments of airplanes in accordance with the rules of
transportation with the proper transport. During the
transportation must be assured position of boxes, which
excludes the possibility of their strokes at one another.
7 CERTIFICATE OF ACCEPTANCE
The device "Fort-9R" caliber 9 mm P.A. factory
number
___________________________________
is made
and accepted in accordance with the requirements of
the normative documents, technical documents and this
device is recognized as suitable for exploitation.
Executed acceptance
_________________
L.S. "
___
"
_____________
20
____
Sold
_______________________________
L.S. "
___
"
_____________
20
____
18
Pull the slide in rearmost position. Check the
cartridge chamber and make sure that it is empty. Release
the slide.
3.3 Field stripping instructions
Push the catch of the recoil spring guide by
wiper.
Hold the device handle by one hand. By trigger
finger press the trigger till hammer angle of deflection will
stay approximate 45°.
Holding the trigger in such position, by another
hand pass slide back in rearmost position, lifting up the
rear edge of the slide and realesing it forward, separate
it from the barrel. Pull out the recoil spring and recoil
spring guide.
3.4 Disassembly of the device
It is not recommended to carry out complete
disassembly often, because it leads to premature wear
of the device mechanism. Carryout complete disassembly
only with strong pollution, continuous staying under
adverse weather conditions (rain, snow, sand dust, high
humidity).
Carry out field stripping of the device as directed
by section 3.3 of this manual.
By drift pin untwist the screws of handle plate
and disconnect them from frame.
Press on the firing spring stop bottom-up by drift
pin and disconnect it with frame.
Knock out by drift pin or by lever the hammer
axis. Get out an ejector from frame and then hammer
with pusher.
11
4 CURRENT REPAIR
Name of failure while
shooting
Possible reason
Troubleshooting
method
Misfire. The slide is
in the forward most
position, the
hammer is deflated,
but the shot is failed
1 Cartridge defect.
2 Condensation of
lubricant; firing-pin
channel is polluted or
the firin g -p in is
rubbed out
3 Precipitating or
fracture of the firing
spring
1 Reload the
device. Carry out
the shot.
2 Unload the
device,
dis a ssem b le it,
exam ine and
clean. If firing-pin is
rubbing out, send
the device to the
workshop.
3 Unload the
device and send it
to the workshop.
Delay of cartridge by
the slide. The slide
stopped w ithout
reaching the forward
most position.
1 Cartridge chamber
pollution.
2 Dam age or
precipitation of the
recoil spring
1 Push the slide
manually forward
and go on firing.
2 U nload the
device and send it
to the workshop.
Cartridge-case is
jammed by the
slide. Slide is in
midtravel
1 Contamination of
the device mobile
parts. Poor round
charge
2 Ejector defect.
1 Pull out the
magazine, take
the slide back,
throw away the
c a rtrid ge -c a se
and go on firing.
2 Unload the
device and send it
to the workshop.
Cleaning of the bore:
- stretch square of cloth through the wipe port.
Mat thickness of cloth should be such that the cleaning
brush enters into the bore with little effort;
- moist the cloth by lubricating oil;
- insert the cleaning brush in the bore and slowly
slide it along the length of the bore several times;
- replace the cloth and clean again;
- repeat cleaning as long as on a clean cloth will
not remain traces of dirt or soot;
- wipe dry the bore by clean and dry cloth.
Clean the slide from dirt and moisture with a cloth
moistened with lubricating oil and squeeze. Thoroughly
clean the place around ejector and firing pin.
The rest of the details and mechanisms, as well
as magazine body, wipe dry with a cloth to the complete
removal of traces of soot, dirt and moisture.
NOTE. During the first cleaning it is necessary
to clean storage compound, carefully wiping details with
the square of cloth, which is slightly moistened by weapon
lubricating oil and squeezed out.
3.7 Inspection of the disassembled device
The inspection of the disassembled device is
carried out after cleaning.
There should not be any defects on details that
affect for the working capacity, durability and safety of
the device, namely:
- there must be no deformation, swellings and
splits on the barrel and chamber;
16 13







