the glass ceramic (it is in the corner of the
glass surface) and an error message that
comes on.
Make sure, you operated the appliance cor-
rectly. If not the servicing by a customer
service technician or dealer will not be free
of charge, also during the warranty period.
The instructions about the customer service
and conditions of guarantee are in the guar-
antee booklet.
INSTALLATION
Warning! Refer to the Safety chapters.
Before the installation
Before the installation of the appliance, re-
cord the information below from the rating
plate. The rating plate is on the bottom of
the appliance casing.
Model ...........................
PNC .............................
Serial number ....................
Warning! During installation in
combustible matter, NIN SEV 1000 and
fire protection guidelines and
regulations of the Association of
Cantonal Fire Insurance shall be strictly
adhered to.
Built-in appliances
Only use the built-in appliances after you
assemble the appliance into correct built-
in units and work surfaces that align to
the standards.
Connection cable
The appliance is supplied with the con-
nection cable.
Replace the damaged mains cable with a
special cable (type H05VV-F or higher).
Speak to your local Service Centre.
Electrical connection
Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must include
an isolating device with at least a 3 mm-
contact separation to enable a simultane-
ous and all-pole cut off from the mains
(according to NIN SEV 1000).
To attach the seal to the rabbet
Clean the rabbet in the work surface.
Bond the seal stripe supplied on the up-
per surface of the rabbet along the edges
of the cut out section.
Cut the seal stripe into four pieces in rela-
tion to the length of the edges of the rab-
bet.
For the four corners of the rabbet the
ends of the seal stripes must be cut into
mitres. Do not bond the ends over one
another.
Bond the seal stripe flush into the corner
of the rabbet. Make sure that no silicon
compound can get below the glass ce-
ramic when grouting.
Do not extend the tapes.
53