User manual
A
If this occurs, close the water tap and
contact the authorized service centre to
replace the hose.
Water drainage
The drain hose should be positioned at a
height of not less than 60 cm and not
more than 100 cm from the floor.
You can extend the drain hose
to maximum 400 cm. Contact
the authorized service centre
for the other drain hose and the
extension.
It is possible to connect the drain hose in
different ways:
1. Make a U shape with the drain hose
and put it around the plastic hose
guide.
2. On the edge of a sink - Fasten the
guide to the water tap or to the wall.
Make sure that the plastic
guide cannot move when the
appliance drains.
Make sure that the drain hose
end is not immersed in the
water. There may be a return of
dirty water into the appliance.
3. To a stand pipe with vent-hole -
Insert the drain hose directly into a
drain pipe. Refer to the illustration.
The end of the drain hose must
always be ventilated , i.e. the
inner diameter of the drain pipe
(min. 38 mm - min. 1.5") must
be larger than the external
diameter of the drain hose.
4. If the end of the drain hose looks like
this (see the picture), you can push it
directly into the stand pipe.
9