Specification Sheet

Table Of Contents
· General protective and hygienic measures:
Wash hands before breaks and at the end of work.
· Breathing equipment:
· Protection of hands:
· Body protection:
Protective work clothing.
· General Information
· Appearance: · pH-value:
Not applicable.
· Form:
Solid.
· Flash point:
Not applicable.
· Odor:
Odorless.
· Flammability (solid, gaseous):
Not determined.
· Odour threshold:
Not determined.
· Decomposition temperature:
Not determined.
· Color:
· Auto igniting:
Product is not selfigniting.
· Danger of explosion:
· Explosion limits: · Vapour density:
Not applicable.
· Lower: .
Not determined
· Evaporation rate:
Not applicable.
· Upper:
Not determined.
· Water:
Insoluble.
· Relative density:
Not determined.
· Dynamic:
Not applicable.
· Partition coefficient (n-octanol/water):
Not determined.
· Kinematic:
Not applicable.
· Organic solvents:
0.00%
· Other information
No further relevant information available.
· Thermal decomposition / conditions to be avoided:
Additional information:
The lists that were valid during the creation were used as basis.
9 Physical and chemical properties
· Information on basic physical and chemical properties
· Exposure controls
· Personal protective equipment:
Filter P2
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.Due to
missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical
mixture.Selection of the glove material on consideration of the penetration times, rates of diffusion and the
Reasonably expected gaseous constituents would include carbon monoxide and carbon dioxide. Ozone and nitrogen
oxides may be formed by the radiation from the arc. One recommended way to determine the composition and
quantity of fumes and gases to which workers are exposed is to take an air sample from inside the welder's helmet if
worn or in the worker's breathing zone. See ANSI/AWS F1.1 and ANSI/AWS F1.2-1992. In order to determine and
evaluation of the existing problem areas, the standards EN ISO15011 –parts 1, 4 can also be applied.
11 Toxicological information
No further relevant information available.
· Hazardous decomposition products:
Reasonably expected fume constituents of this product would include: cupper oxide, copper oxide, chromoxide, nickel oxide.
Penetration time of glove material:
10 Stability and reactivity
· Reactivity
No dangerous reactions known.
· Conditions to avoid
No further relevant information available.
According to
product specification.
Product does not present
an explosion hazard.
No decomposition if used and stored according to specifications.
· Chemical stability
· Possibility of hazardous reactions:
The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed
· Eye protection:
Not required.
Wear hand, head, and body protection which help to prevent injury from radiation, sparks, and electrical shock. See
ANSI Z49.1. At a minimum this includes welder's gloves and a protective face shield, and may include arm
protectors, aprons, hats, shoulder protection, and well as dark substantial clothing. Train the welder not to touch live
electrical parts and to insulate himself from work and ground.
Information on toxicological effects
Heat protection gloves (non-combustible)
· Incompatible materials: