User's Manual
29
DTIM Interval: This value indicates the interval of the Delivery Traffic Indication Message
(DTIM). A DTIM field is a countdown field informing clients of the next window for
listening to broadcast and multicast messages. When the Access Point has buffered broadcast
or multicast messages for associated clients, it sends the next DTIM with a DTIM Interval
value. Clients can hear the beacons and awaken to receive the broadcast and multicast
messages.
Space In Meter: This space in meter is used for extending ACK time-out destination. The
setting range is 0-36000.
Preamble Type: The Preamble defines the length of the PLCP synchronization field for
communication between the Access Point and Network Card. Select the appropriate preamble
type and press the Apply button to set it. The default setting is ‘Auto’.
Antenna: Choose the antenna type you like to use. They are auto, primary and secondary.