User Manual

Parts List
C.TXR−2
Foot Control, 230V
Form DN 12/10
FOREDOM The Foredom Electric Company
16 Stony Hill Rd., Bethel, CT 06801 203−792−8622
Fax: 203−796−7861
www.foredom.net
}
Qty
DescriptionPart No.Item
1
CoverCP10852B
1
1
Trigger Switch, 250VCP11027
2
2
Screw, #6−32 x 5/16, SlottedCP10571
3
1
Fish Paper
CP10525
4
1
Circuit BoardCP10521
5
1
Base
CP10851
6
1
Front Base Pad
CP10859
7
1
Screw, #6−32 x 1"CP10856
8
1
Washer, #6
CP10862
9
1
Rear Base Pad
CP10860
10
2
Strain ReliefCP10003−3
12
1
Male Cordset or Substitute OptionCP10541
11
1
Female CordsetCP10868
13
1
Wire 3", Brown, Tinned
CP11163
14
1
Wire 3", Brown
CP11162
15
Tigger Switch
5
6
1
4
3
2
AC Male Plug
to Power Source
BLU
GRN/YLW
GRN
(GRNYLW)
BLK
(BRN)
BRN
BRN
Wiring Diagram
Insert adjustment screw (8) through washer (9) and into post
slot and threaded insert in cover (1). Tighten with screwdriver
until cover is just touching the trigger switch pushrod.
Do not
tighten the screw further
to avoid pressing the Switch Pushrod
into a permanently "on" position.
Position wires around adjustment screw post so wires will not
interfere with cover travel.
Connect Wires to New Trigger Switch as shown in the
Wiring Diagram. Push wires all the way in, so that no bare wire
is exposed. On Screw Terminal 1, push the wire lead all the way
into the socket then tighten the screw firmly. Push the other wire
lead all the way into terminal 6. Pull on all the wires, making sure
they are secure. Place Switch back into Base mounting bracket.
Snap cover (1) onto hinge posts on top of rear corners of base (6).
Disconnect Foot Control from Motor and Wall Outlet.
Instructions for Removing
and Replacing Trigger Switch
Unscrew cover adjustment screw (8).
Using flat blade of screwdriver inserted at Point A
between Cover (1) and Base (6), carefully pry Cover off.
5.
Remove Trigger Switch (2) from Base mounting bracket.
On older Switches, all the terminals will be push-in, spring clamp
type. On newer Switches, some terminals have screw fasteners.
To remove wires from the push-in terminals, insert 1.3mm [.05in]
approximate diameter pin or the blade of a jeweler's screwdriver
all the way into the terminal socket to release the spring clamp.
Grasp the tool and wire and pull them together out of the socket.
If you have difficulty removing the wires from the push-in terminals
and you have wire-cutting, stripping, and soldering tools, you can
cut the wires off where they exit from the terminals. To prepare
the cut wires for installation into the replacement Switch, strip
them back exactly 8.25 mm [5/16 in], then apply solder to the
stripped ends to fuse the strands together.
4.
3.
6.
7.
8.
2.
1.
Female Receptacle
to Motor
For use with LX 230V Motors
and discontinued TX 230V Motors.
Cordset Option
Part No.
Cordset Descrption
CPOption20
CP10545
No Plug, Europe
CPOption21
CP10553
Male, United Kingdom
CPOption22
CP10554
Male, Continental Europe
CPOption25
CP10555
Male, India 10A
CPOption26
CP10556
Male, Australia