Installation Supplement

Both grilled and slot vents are carried in stock as well as plain and
insulated ducting and ducting vents.
The Hearth
The stove should be positioned on or above a non-combustible hearth
and the hearth should extend a minimum of 300mm in front of the stove
door if the room has a combustible floor.
If the stove is to be set into a traditional fire surround then it would
normally be positioned directly onto the hearth.
If it is to be set into the wall in a more contemporary style then it is usual
to leave at least 300mm below the door height. The stove can also be
placed higher than this with a wood store below it.
The 300mm hearth required in front of the stove can be at the same
height as the stove. If the stove is raised up and the hearth is to be at
floor level then we recommend that the hearth extends slightly further
forward.