Operation Manual

75
BLITZ
G BG B
G BG B
G B
10-15
10.8 FITTING A NEW HORIZONTAL VICE CYLINDER
1) Turn the pneumatic master switch to “0” and padlock it, then turn the main switch to “0”.
2) Remove the vice pad.
3) Undo the release handle “A” - Fig. 10-14 and remove the cylinder.
4) Disconnect the air tubes “B” - Fig. 10-14.
5) Fit the pad to the new cylinder, replacing it with a new one if necessary.
6) Position the new cylinder inside its housing, securing it with the release handle “A”.
7) Connect the air tubes “B” to the union on the new cylinder.
8) Release the pneumatic master switch and turn it to “I” then turn the main switch to “I”.
9) Carry out a few test runs.
10-14
B
A