Operation and Service Manual

36 Tempo Undercounter Ice Machine Bin
Service Mode/Self Diagnostics
Note: To enter Service Mode press and hold the hidden button behind Follett for 10 seconds on user
interface. After 5 minutes of non-use system will exit Service Mode.
LED
Readout
Sub
Menu
Function Change
Settings
Press Light
button to
Toggle
Component
ON/OFF
Comments
00 Exit X X
01 Thermistor 1 - Temp not including offsets X X Ice bin temperature
02 Thermistor 2 - Temp not including offsets Not Used
03 Thermistor 3 - Temp not including offsets Not Used
04 Thermistor 4 - Temp not including offsets Not Used
05 Thermistor 1 offset (+/- 10) X X Setting off-set +/- 10 degrees F
06 Thermistor 2 offset (+/- 10) Not Used
07 Thermistor 3 offset (+/- 10) Not Used
08 Thermistor 4 offset (+/- 10) Not Used
09 Thermistor 2 set point Not Used
10 Thermistor 3 set point Not Used
11 Thermistor 4 set point Not Used
12 Defrost Interval (0 to 99 hr) Not Used
13 Defrost Duration (0 to 99 min) Not Used
14 Error Log (See Appx D) X X
15 Clear Error Log (Hold Light Key Until Cleared) X X
16 Thermistor 1 Differential (+5) Not Used
17 Thermistor 3 Differential (+5) Not Used
18 Evaporator Fan ON Delay (0 to 99 sec) Not Used
19 Evaporator Fan OFF Delay (0 to 99 sec) Not Used
20 00 Exit X X Press light once and use arrows
to select output (Once selected,
light toggles state)
01 Not Used
02 Not Used
03 Dump Solenoid X X Pressing light button turns
solenoid ON and OFF
04 Reservoir Fill Solenoid X X Pressing light button turns
solenoid ON and OFF
05 Auger Motor X X Pressing light button turns Auger
Motor ON and OFF
06 Condenser Fan X X Pressing light button turns
Condenser Fan Motor ON and
OFF
07 Interior Light X X Pressing light button turns
Interior Light ON and OFF
08 Not Used
09 Not Used
10 Not Used
11 Not Used
12 Not Used