U155 User's Manual

Plumbing
Dispenser - 3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan
3/4" PVC pipe nipple for bath overflow
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per
30.4cm run) slope on drain line run.
Icemaker - Refer to Icemaker Installation Manual packed with icemaker for installation instructions
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water cooled condenser only)
1/2" FPT condenser drain (water cooled condenser only)
Water disconnect within 10 feet (3 meters) of dispenser is suggested for automatic load units.
Beverage connections
Dispenser is provided with 1/4" syrup, 3/8" carbonated water and 3/8" plain water pigtails
Clearance and access information
51" (1296mm) above counter
12" (305mm) on side opposite tower, below counter
Counter front or rear panel must be removable for service access to both sides of dispenser and
icemaker(s), (if any)
Below counter access to drain clean-out required on utility side of dispenser
See Icemaker Installation Manual packed with icemaker(s) for clearance requirements for automatic load
dispensers
3
17"
(432mm)
6"
min
12"
min
18.9"
(481mm)
PVC
joint
drain
slip
3/4"
beverage line
air break*
electrical
connections
31.25"
(794mm)
21.75"
(553mm)
28"
(712mm)
counter top
49.75"
(1264mm)
(8 valve unit)
(10 valve unit)
37.25"
(947mm)
Manual load units
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers
27.375"
(696mm)
ice transport
tube entrance
6"
(153mm)
25.8"
(656mm)
bin
signal
power
8.75"
(223mm)
3/4 PVC
slip joint
drain
18.5"
(470mm)
air
beverage
waterbath
overflow
break*
beverage
drain pan
drain
*DO NOT
CONNECT TO
DRAIN SYSTEM
3.5"
(89mm)
Side view - right hand dispenser
(side opposite dispense tower)
Front view units with up to 10 beverage valves