Spec Sheet
3
Form# 3265
Ice Manager diverter valve system Ice Manager diverter valve system
Configuring the Ice Manager diverter valve system (Continued)
4. Evaluate site for location of equipment
Lane 1 and Lane 2 dispensers or bins
• Refer to dispenser or bin specifications for required clearances
• See drawings below for required clearances for Ice Manager
diverter valve system
Follett Horizon Elite ice machine
• 10' (3 m) maximum distance from Horizon Elite ice machine to
diverter valve
• See spec sheets 7030, 7035, 8180 and 3311 for utility
requirements anddimensions
Diverter valve
• 8' (2.4 m) maximum distance from diverter valve module to
electricoutlet
• 75' (22.8 m) maximum distance from diverter valve to Lane 1 and
Lane 2 dispensers or bins
• Drain required, 15' (4.6 m) drain tube provided
Control panel
• 30' (9.2 m) max. distance from control panel to diverter valve
5. Determine length of ice transport tubes
Lane 1: (approx. length): ____________________
Lane 2: (approx. length): ____________________
Use the following guidelines to determine length of the
icetransport tube run from the diverter valve to each bin
ordispenser.
• Length of ice transport tube from diverter valve module to each
dispenser or bin can be specified in 5' (1.5 m) increments from
10' - 75' (3.0 m - 22.8 m) ¹
• Maximum vertical rise of ice transport tube – 10' (3 m)
• Horizontal run should be pitched so that melt water drains back
todiverter valve module. Run must have 1⁄4" per foot pitch.
• No dips or traps in the tube run
¹ Lengths to include any bends and turns needed to connect components.
6. Site plan drawings
Installation may be performed by an authorized installer
contracted by Follett. Contact factory for details.
Required clearances for Ice Manager diverter valve system
Top mount on a bin (minimum bin width)
Sensor distribution unit
(bins and ice and beverage dispensers only)
LANE 2
LANE 1
Diverter valve
Front View
Side View
Front View
12.00" (30.5 cm)
clearance
6.00" (15.24 cm)
clearance
6.00" (15.24 cm)
clearance
6.00" (15.24 cm)
clearance
mounting
bracket
mounting
bracket
bin / dispenser topbin / dispenser top
Insulated transport tube
(RIDE applications)
12.00" (30.5 cm)
clearance
Front View Side View
Front View Side View
min.
1. 00" (2.54 cm)
clearance
4.12"
(10.46 cm)
Y
min.
0.50" (1.27 cm)
clearance
X
bin top
Horizon Elite ice machine
sensor
distribution
unit
min.
2.00"
(5.08 cm)
clearance
3.00" (7.62 cm) dia. hole required
to run tubing through walls
Note: For 30.00" (76.2 cm) Follett bin, sensor distribution
unit may be placed behind ice machine.