Ice Manager Diverter Valve System Operation and Service Manual 25
Sensor Reading:
Lane 1: ___"
Lane 2: ___"
Status : OK
Fig. 43
Mode
select
Lane 1
Lane 2
Lane 1 Setup:
Full: 10.0"
Min: 14.0"
Dif: 3.0"
Fig. 44
Ice level set points
Ice level set points are set at the factory and normally do not
need to be changed. Setting recommendations are shown in the
table below. Please contact Follett Technical Services toll free at
(877)612-5086 or +1 (610) 252-7301 prior to changing ice level set
points.
Factory settings
LANE
1
Full 10"
Min 14"
Dif 3"
LANE
2
Full 10"
Dif 3"
To view ice levels
1. Locate LED screen on Ice Manager control panel. Initial screen
will show ice levels for lane 1 and lane 2 and diverter valve
status (Fig. 43).
To view set points
1. Press and hold both MODE SELECT and LANE 1 buttons until
LANE 1 SETUP appears on the display (Fig. 44).
Note: Default/factory-set ice level sensor settings are shown.
2. To view lane 2, press MODE SELECT to navigate to lane 2
setup (Fig. 45).
To change set points
1. Press and hold both MODE SELECT and LANE 1 buttons until
LANE 1 SETUP appears on the display (Fig. 44).
Note: Default/factory-set ice level sensor settings are shown.
2. Press LANE 1 button to move through FULL, MIN and DIF ice
level sensor settings. When selected, choice will ash (Fig. 46).
3. Press MODE SELECT button to change ice level sensor set
point (Fig. 47).
4. Press LANE 1 button to increase ice level sensor set point
and LANE 2 to decrease ice level sensor set point, (Fig. 48) to
correspond to the drop-in dispenser ice level sensor settings
listed in table above.
5. Press MODE SELECT to save new ice level sensor setting
(Fig. 49).
6. Press LANE 1 to continue to navigate through and set the Full,
Min, and Dif ice level sensor settings for lane 1 (Fig. 50).
7. Press MODE SELECT to navigate to lane 2 setup (Fig. 51).
8. Repeat steps 2 through 6 to complete changes to lane 2 ice
level sensor settings.
Mode
select
Lane 1
Lane 2
Lane 1 Setup:
Full: 10.0"
Min: 14.0"
Dif: 3.0"
Fig. 46
Lane 1 Setup:
Full: 10.0"
Min: 10.0"
Dif: 9.0"
Mode
select
Lane 1
Lane 2
Fig. 47
Lane 1 Setup:
Full: 10.0"
Lane 1/2: Scroll
Mode: Save Value
Mode
select
Lane 1
Lane 2
Fig. 48
Lane 1 Setup:
Full: 10.0"
Min: 10.0"
Dif: 9.0"
Mode
select
Lane 1
Lane 2
Fig. 49
Mode
select
Lane 1
Lane 2
Lane 1 Setup:
Full: 10.0"
Min: 14.0"
Dif: 3.0"
Fig. 50
Lane 2 Setup:
Full: 10.0"
Dif: 3.0"
Mode
select
Lane 1
Lane 2
Fig. 51
Lane 2 Setup:
Full: 10.0"
Dif: 3.0"
Mode
select
Lane 1
Lane 2
Fig. 45