Installation Guide
Ice Manager Diverter Valve System Installation Instructions 5
Temperature and humidity requirements
• All components, including ice transport tube, must be
operated in ambient temperatures between 40 F and
120 F (5 C and 49 C)
• Relative humidity not to exceed 55%
Ice transport tube requirements
• Maximum vertical rise of 10' (3m) from ice machine to
highest elevation of tube
• Use one continuous piece of ice transport tube. Do not
splice.
• Horizontal run should be pitched so that melt water
drains back to diverter valve. Ice transport tube run
must have at least 1/4" per foot pitch (6.4mm/0.3m)
➎
• Secure ice transport tube as needed to eliminate dips
and traps
• Insulate all ice transport tube runs, making sure that
sensor cable runs outside of the insulation
➏
Ice transport tube and cable distance
requirements
• Ice machine to diverter valve - maximum run of
10' (3m)
• Diverter valve to operator control panel - maximum
run of 30' (9m)
• Diverter valve to ice receptacle - maximum run of
75' (23m)
• Distance between ice transport tube supports -
maximum of 2' (0.6m)
Operating temperature requirements
• Ice Manager diverter valve system components,
including ice transport tube must be operated in
ambient temperatures between 40 F and 120 F
(4.5 C and 49 C)
➏
➎
1/4˝
1'
max. length of 10' (3m)
of cable and transport tube between
ice machine and diverter valve
➌
➍
➊
1410A/W
1010A/W
NEMA
6-20
NEMA
5-15
NEMA
5-15
NEMA
6-15
➋
max. length of 30' (9m)
of cable between
diverter valve
and operator
control panel
8' (2.4m)
cord
6' (1.8m)
cord
max. length of 75' (23m)
of cable and transport tube between
diverter valve and ice storage unit
ice transport tube
sensor cable
max. length of 75' (23m)
of cable and transport tube between
diverter valve and ice storage unit
ICE MACHINE
DIVERTER
VALVE
insulation
max. length of 2' (.6m)
between supports
CONTROL
PANEL
1010N/R 1810N/R
1410N/R 2110N/R
1650N/R