Installation Guide
4 Ice Manager Diverter Valve System Installation Instructions
Electrical - ice machine ➊
• 1010 (A/W) 208-230/60/1, 11A, max. ice machine fuse 15A
• 1410 (A/W) 208-230/60/1, -5%/+10% under peak load. 16A, max. ice
machine fuse 20A
• 1010/1410/1810/2110 (R/N)
Evap. 115/60/1, 6A; max. fuse 15A
• 1650 (R/N)
Evap. 115/60/1, 6A; max. fuse 15A
Condenser (R models only)
1010R 1410R 1810R 2110R
Single 3-Phase Single 3-Phase Single 3-Phase Single 3-Phase
Electrical 208-230V, 60 Hz
Max Circuit
HVACR
Breaker
Size
15A 15A 30A 25A 45A 25A 45A 30A
Min Circuit
Ampacity
10.7A 9.9A 19.3A 14.2A 26.2A 15.7A 27.1A 19.9A
Electrical - Ice Manager ➋
• 115/60/1, 1.5 amps; max. fuse 15 amps
Drains
• Ice Manager - 3/8" (9.5mm) barb - 15 ft.
(4.6m) 3/8"(9.5mm) I.D. tubing provided
Potable water supply - ice machine
➌
• 10 - 70 psi (69 - 483kpa)
• 45 F to 90 F (7 C to 32 C)
• Follett recommends the use of an in-line
water lter (item# 00130286)
Condenser water supply for water-
cooled systems
➍
• 10 psi min.; 150 psi max. (69kpa min.;
1034kpa max.)
• 45 F to 90 F (7 C to 32 C)
• 1.5 gallons per minute (5.68 liters per
minute)
Ice Manager - Site preparation and system overview
➏
➎
1/4˝
1'
max. length of 10' (3m)
of cable and transport tube between
ice machine and diverter valve
➌
➍
➊
1410A/W
1010A/W
NEMA
6-20
NEMA
5-15
NEMA
5-15
NEMA
6-15
➋
max. length of 30' (9m)
of cable between
diverter valve
and operator
control panel
8' (2.4m)
cord
6' (1.8m)
cord
max. length of 75' (23m)
of cable and transport tube between
diverter valve and ice storage unit
ice transport tube
sensor cable
max. length of 75' (23m)
of cable and transport tube between
diverter valve and ice storage unit
ICE MACHINE
DIVERTER
VALVE
insulation
max. length of 2' (.6m)
between supports
CONTROL
PANEL
1010N/R 1810N/R
1410N/R 2110N/R
1650N/R