Installation Guide

10 Ice Manager Diverter Valve System Installation Instructions
front of
dispenser
or bin top
C
L
C
L
front of dispenser or bin top
3-1/2"
(88.9mm) dia.
template
All other dispensers
front of
dispenser
or bin top
back of
dispenser
or bin top
ED300 dispenser only
4"
(102mm)
4"
(102mm)
4"
(102mm)
R1 3/4"
(19mm)
110CM Symphony Plus w/IMDV
R1.750
5"
(127 mm)
5" (127 mm)
4"
(102 mm)
30” Lancer Sensation and Touchpoint w/IMDV
10.00"
9.00"
4"
ø3.5"
hole saw
C
L
C
L
4
"
(102 mm)
ø3.5"
hole saw
REAR OF
DISPENSER LID
(UNDERSIDE)
Freestyle 9000
FRONT OF
DISPENSER LID
(UNDERSIDE)
Prepare ice & beverage dispenser/bin top
Using drawing above for your application, locate the
proper location of ice & beverage dispenser (IBD) to
place the supplied template
Using supplied template and 3.5" dia. hole saw, cut
holes per template
Note: Use a hand saw or similar tool to complete the
cut out.
Mount sensor distribution unit
Unscrew cap nut and remove center assembly
Loosen screws and remove cover
Turn short arm of angle rods so unit can be lowered
into hole of IBD top
Position unit into IBD top with tube at the front
Turn angle rods to face outward
Tighten wing nuts until arms of both rods press rmly
against underside of IBD top securing body of sensor
distribution unit
5
Ice & beverage dispenser/bin