Spec Sheet

3
Form# 8180
Remote 1810, 2110 series ice machine
Specification, condenser unit
Horizon Elite 1810 series Horizon Elite 2110 series
W1 Width 30.00" (76.2 cm) – all models 30.00" (76.2 cm) – all models
D1 Depth (hail guard included) 38.50" (97.8 cm) – all models 38.50" (97.8 cm) – all models
H1 Height 25.75" (65.4 cm) – all models 25.75" (65.4 cm) – all models
Electrical single phase – 208‑230/60/1
three phase – 208‑230/60/3
single phase – 208‑230/60/1
three phase – 208‑230/60/3
Operating power single phase – 6.0 kW
three phase – 3.6 kW
single phase – 6.2 kW
three phase – 4.6 kW
Minimum circuit ampacity single phase – 26.2 A
three phase – 15.7 A
single phase – 27.1 A
three phase – 19.9 A
Maximum circuit HVACR breaker size single phase – 45 A
three phase – 25 A
single phase – 45 A
three phase – 30 A
Outdoor condensing unit operating limits
(air temperature)
min ‑20 F (‑29 C)
max 120 F (49 C)
min ‑20 F (‑29 C)
max 120 F (49 C)
Maximum refrigerant line run length 75' (22.9 m) 75' (22.9 m)
Maximum line rise above evaporator 35' (10.7 m) 35' (10.7 m)
Evaporator mounting above condenser 15' (4.6 m) 15' (4.6 m)
Maximum refrigeration line drop without oiltrap 15' (4.6 m) 15' (4.6 m)
Refrigerant charge 14.5 lb required at installation 14.5 lb required at installation
Approximate ship weight 305 lb (138 kg) 305 lb (138 kg)
Approximate net weight 295 lb (134 kg) 295 lb (134 kg)
NOTE:
1. The entire liquid line should be insulated separately from the suction line.
W1
D1
H1
Dimensional drawing