Installation Instructions for RIDE Models

15
HARMONY and Symphony Plus RIDE Technology remote
Connect utilities to louvered docking assembly.
6
External connections
Refrigerant
6.2
Braze supplied quick-connect lines onto
stub-ins
.
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
Rough-in ice machine potable water
supply
.
3/8” push-in connection will be made at
shut-off valve inside machine
Remove access panel if necessary
.
Connect the silicone tubing to the ice
machine 3/4” drain barb
.
Assemble the 3/4” barb x 3/4” FPT to the
3/4” MPT x 1” slip. Connect the other end
of the silicone tubing to the 3/4” barb
.
Connect the 1” slip tting to the 1” stand
pipe/drain
.
Note: Minimum 8” radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4” per foot pitch
(6,4mm/0,3m).
Apply Petrol-gel to barbed drain tting
Replace access panel.
Water and drain
6.1