Spec Sheet

Remote 1810, 2110 series ice machine
801 Church Lane | Easton, PA 18040, USA
1.800.523.9361 | 1.610.252.7301 | follettice.com
8180‑202004 | © Follett LLC
Ice production – Horizon Elite 1810 series
Inlet water
temperature
F (C)
Ambient air temperature F (C)
60 (16) 70 (21) 80 (27) 90 (32) 100 (38)
lb (kg) production in 24 hr
50 F (10 C)
1859 (844) 1784 (810) 1685 (765) 1616 (734) 1500 (681)
60 F (16 C)
1723 (782) 1684 (765) 1578 (716) 1563 (710) 1409 (640)
70 F (21 C)
1620 (735) 1594 (724) 1514 (687) 1420 (645) 1319 (599)
80 F (27 C)
1550 (704) 1487 (675) 1485 (674) 1351 (613) 1299 (590)
90 F (32 C)
1471 (668) 1435 (651) 1370 (622) 1285 (583) 1207 (548)
Ice production – Horizon Elite 2110 series
Inlet water
temperature
F (C)
Ambient air temperature F (C)
60 (16) 70 (21) 80 (27) 90 (32) 100 (38)
lb (kg) production in 24 hr
50 F (10 C)
2039 (925) 2039 (925) 1934 (877) 1825 (828) 1703 (772)
60 F (16 C)
1943 (881) 1888 (856) 1878 (852) 1710 (776) 1584 (718)
70 F (21 C)
1833 (831) 1781 (808) 1789 (811) 1634 (741) 1489 (675)
80 F (27 C)
1754 (796) 1686 (765) 1643 (745) 1535 (696) 1426 (647)
90 F (32 C)
1650 (748) 1603 (727) 1577 (715) 1457 (661) 1395 (633)
ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.
Agion is a registered trademark of Sciessent LLC.
HORIZON ELITE, ICE•DEVICE, ICE MANAGER, MICRO CHEWBLET, SAFECLEAN PLUS, SANISPONGE, SYMPHONY PLUS and VISION are trademarks of FollettLLC.
CHEWBLET, FOLLETT and RIDE are registered trademarks of Follett LLC, registered in the US.
Follett reserves the right to change specifications at any time without obligation. Certifications may vary depending on country of origin.
Remote condensing unit
Condensing unit installation specifications
Important specifier notes
air in
exhaust
48.00"
(121.9cm)
48.00"
(121.9cm)
24.00"
(61.0cm)
24.00"
(61.0cm)
36.00" (91.4 cm)
height clearance
1. Provide front, back, top and side clearances
asshown.
2. The maximum refrigerant line run length is
75' (22.9 m). Installations require 14.5 lb of
refrigerant.
3. The maximum line rise above the evaporator is
35' (10.7 m). Condensing unit above evaporator
unit – 35'(10.7m) (installations with rise over
20' (6.1 m) require additional suction line s-trap
at midpoint rise).
4. The evaporator can only be mounted a maximum
of 15' (4.6 m) above the condensing unit.
Note: The service loop is not included when
calculating length, rise or drop in the tubingrun.
Note: To connect evaporator/ice machine to rack systems, see page 3.