Spec Sheet
3
Form# 7035
Remote 1010, 1410 series ice machine
Specification, condenser unit
Horizon Elite 1010 series Horizon Elite 1410 series
W1 Width 36.25" (91.4 cm) – all models 36.25" (90.1 cm) – single phase
37.75" (95.9 cm) – three phase
D1 Depth 25.50" (64.8 cm) – all models 25.50" (64.8 cm) – single phase
28.25" (71.6 cm) – three phase
H1 Height 26.10" (66.3 cm) – all models 26.10" (66.3 cm) – single phase
19.75" (50.2 cm) – three phase
Electrical single phase – 208-230/60/1
three phase – 208-230/60/3
single phase – 208-230/60/1
three phase – 208-230/60/3
Operating power single phase – 2.4 kW
three phase – 2.2 kW
single phase – 4.2 kW
three phase – 3.0 kW
Minimum circuit ampacity single phase – 10.7 A
three phase – 9.9 A
single phase – 19.3 A
three phase – 15 A
Maximum overcurrent protection single phase – 15 A
three phase – 15 A
single phase – 30 A
three phase – 20 A
Outdoor condensing unit operating limits
(air temperature)
min -20 F (-29 C)
max 120 F (49 C)
min -20 F (-29 C)
max 120 F (49 C)
Maximum refrigerant line run length 100' (30.5 m) 100' (30.5 m)
Maximum line rise above evaporator 35' (10.7 m) 35' (10.7 m)
Evaporator mounting above condenser 15' (4.6 m) 15' (4.6 m)
Maximum refrigeration line drop without oil trap 15' (4.6 m) 15' (4.6 m)
Refrigerant charge 12.5 lb required at installation 12.5 lb – single phase
10 lb – three phase
required at installation
Approximate ship weight 260 lb (118 kg) 270 lb (122 kg) – single phase
230 lb (104 kg) – three phase
Approximate net weight 250 lb (114 kg) 260 lb (118 kg) – single phase
210 lb (95 kg) – three phase
NOTE:
1. The entire liquid line should be insulated separately from the suction line.
W1
D1
H1
W1
D1
H1
1010/1410 single phase
1010 three phase
1410 three phase
Dimensional drawing