Installation Instructions

5
ICE MANAGER remote condensing
Prepare the installation site.
2
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
Electrical
120/60/1-5 amps
Potable water supply
(3/8” push-in internal connection, 3/8” OD tubing required)
10-70 psi (69-483kpa)
45-90 F (7-32 C)
Follett recommends the use of an in-line water ltration system (item# 00130286)
• This equipment is to be installed with adequate backow protection to comply with applicable
federal, state, and local codes
Drain
(3/4” MPT)
• The drain line from the ice machine must have at least 1/4” per foot pitch (6,4 mm/0,3 m)
Refrigeration lines
5/8” (15,8 mm) diameter suction line (insulated)
3/8” (9,5 mm) liquid line
Installation site requirements
2.1
3/8" (9,5mm)
NEMA
5-15
1'
1/4" per foot
(6,4 mm per 0,3 m)
5/8" (15,8 mm)