Spec Sheet

6
Form# 7030
Self-contained 1010, 1410 series ice machine
3 – Undercounter/in-cabinet mounting and ventilation (continued)
Using grilles by others/alternate cabinet ventilation
Cabinets with ventilation or louvers other than those provided require special consideration to provide proper ventilation.
Recirculation of hot air will reduce ice machine performance and can cause ice machine outages.
18.00" (45.7 cm)
minimum
18.00" (45.7 cm)
minimum
Grilles by others/
alternate cabinet
ventilation
All counter ventilation
within 18.00" (45.7 cm) of
air inlet must be blocked to
prevent exhaust-air recirculation
air in
exhaust
exhaust
Cabinet door
must mate directly
to air intake gasket
Minimum open air space
Grilles by others/
alternate cabinet ventilation
x
x
xx
= sq. in. of open air space
= (# of openings)
minimum 250 sq. in.
open air space
yn
n
side
view
y
Horizon Elite ice machine
air intake gasket
cabinet door
door & gasket
must mate
directly
Important specifier notes for using grilles supplied by others/alternate cabinet ventilation
1. Exhaust must be at least 18.00"(45.7cm) from air intake (exhaust air must
notrecirculate with intake air).
2. Cabinet interior must be open to allow for unrestricted exhaust airflow.
3. Ice transport tube needs minimum 1/4" per foot (2 cm per meter) pitch toward
ice machine and should be secured to prevent dips and traps from forming.
4. Ducting must be provided if cabinet door does not mate directly to air
intakegasket.
5. Cabinet interior must provide a minimum clear space of 23.50" (59.7 cm) high
by 25.25" (64.1 cm) deep.
6. Grilles by others must meet minimum requirements for open air space
shownabove.
7. Utilities should be conveniently located as shown.