Installation Instructions

HARMONY • RIDE Technology Horizon Elite 710/1010/1410
7
4. Mount Ice Machine
Mounting options: Cabinet, Wall, Stand
In cabinet Wall bracket Stand
22.00"
(55.9 cm)
25.50"
(64.8 cm)
29.50"
(74.9 cm)
28.70"
(72.9 cm)
21.00"
(53.3 cm)
6.00"
(15.24 cm)
4.1 Ice machine in cabinet
Ice machines can be installed undercounter/in-cabinet to ll bins or dispensers using RIDE technology. Care
must be taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice
machine outages.
DOCKING STATION: Horizon
(See detail drawing on page 9)
§ Position and screw louvered docking assembly to the bottom of counter inside of access panel/door 2" (51 mm)
from the front edge of the cross brace
§ The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
§ There must be no lip or edge that would hinder the ice machine from sliding in or out of the louvered docking
station
INTAKE AND EXHAUST GRILLE PLACEMENT: Air-cooled models only
(See detail drawing on page 9)
§ Position the intake grille cut out in the access panel/door
Note: Ice machine must be aligned with cut out and inside of access panel to provide a tight seal and prevent
recirculation of hot exhaust air.
§ Left edge of cutout should be 2.25" (57 mm) from the left side of the ice machine
§ Bottom edge of cutout should be 2" (51 mm) from the bottom of the ice machine
§ Position supplied exhaust grille at least 18" (458mm) away from intake grille
.
Where possible, install exhaust grille to the rear or side of the base cabinet.
§ If not using supplied grille, air circulation requirements below must be met:
250 sq. in (1613 sq cm) intake air, 250 sq. in (1613 sq. cm) exhaust air