Spec Sheet
5
Form# 7030
Self-contained 1010, 1410 series ice machine
3 – Undercounter/in-cabinet mounting and ventilation
Using Follett supplied grilles
Horizon Elite ice machines can be installed undercounter/in‑cabinet to fill bins or dispensers using RIDE technology. Care must be
taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice machine outages.
23.50"
(59.69 cm)
minimum
drain
water
electric
see dispenser
specification
sheet for
installation
requirements
Cabinet door
Ice transport tube
Horizon Elite
ice machine
Supplied
grilles
minimum 1/4" per foot
(2 cm per meter)
pitch toward ice machine
secure to prevent dips
and traps from forming
exhaust
18.00" (45.7 cm)
minimum
air in
12.00" (30.5 cm) minimum
between ice machine
and dispenser
must mate directly
to air intake gasket
25.25" (64.1) cm)
minimum
r
Horizon Elite ice machine
Completed installation with
gasket and door in place –
Side view
air intake gasket
cabinet door
supplied intake grille
Front
cutout for supplied air intake grille
locating
cutout
24.00"W x 16.00"H (61.0 cm x 40.6 cm)
25.25" (64.1 cm) min.
23.50"
(59.7 cm)
minimum
bottom of ice machine
side of ice machine
cutout
2.00"
(5.08 cm)
2.25" (5.72 cm)
door & gasket
must mate
directly
Important specifier notes for using Follett supplied grilles
1. The supplied exhaust grille must be located at least 18.00"(45.7cm) from the
supplied air intake grille (exhaust air must notrecirculate with intake air).
2. Cabinet interior must be open to allow for unrestricted exhaust airflow.
3. Ice transport tube needs minimum 1/4" per foot (2 cm per meter) pitch toward
ice machine and should be secured to prevent dips and traps from forming.
4. Cabinet door must mate directly to air intake gasket.
5. Cabinet interior must provide a minimum clear space of 23.50" (59.7 cm) high
by 25.25" (64.1 cm) deep.
6. Cutout for supplied grilles must meet minimum size requirements
shownabove.
7. Utilities should be conveniently located as shown.