Installation Instructions

5
Cornelius • RIDE Technology self-contained
NEMA
6-15
H_C1010A/W
H_C1410A/W
NEMA
6-20
NEMA
5-15
HCD710A
1'
1/4" per foot
(6,4 mm per 0,3 m)
2 ft. x 1" OD
silicone tubing
and ttings
provided
Prepare the installation site.
2
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
Electrical
• H_C1010/1410(A/W)JS 208-230/60/1-15A • HCD710APS 115/60/1-15A
Potable water supply
(3/8" push-in internal connection, 3/8" OD tubing required)
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water ltration system (item# 00130286)
This equipment is to be installed with adequate backow protection to comply with applicable
federal, state, and local codes
Condenser water supply for water-cooled systems
(1/4" FPT inlet, 1/4" FPT outlet)
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
(3/4" Barb)
The drain line from the ice machine must have at least 1/4" per foot pitch (6,4mm/0,3m)
Installation site requirements
2.1