Horizon Elite™ Ice Machine with RIDE™ Technology Installation Instructions for Harmony™ HMD/HCD710AHS, HCC/HCE/HMC/HME: 1010AHS, 1010WHS, 1410AHS, 1410WHS (See model number configurator on page 2 for details.) Order parts online www.follettice.com self-contained Horizon ice machines with RIDE technology to fit most countertop dispensers manufactured by Cornelius • Lancer • SerVend 801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.
Chewblet® Ice Machine Model Number Configurations HC Icemaker MC Maestro™ Chewblet® (425 Series) HC Horizon Chewblet (710, 1010, 1410, 1810, 2110 Series) HM Horizon Micro Chewblet Voltage D 1810 A V Series S Application Configuration Vision™ Harmony™ Ice storage bin Drop-in Ice Manager diverter valve system P Cornelius Profile PR150 S RIDE™ (RIDE remote ice delivery equipment) T Top-mount Condenser 425 up to C 208-230/60/1 (icemaking head) Self-contained only.
Contents Unpack.............................................................................................................................................................................4 Unpack Ice Machine...................................................................................................................................................4 Site Preparation...........................................................................................................................................
1. Unpack Carefully unpack and inspect the contents of your Follett ice machine. 1.
2. Site Preparation Provide drainage, potable water supply and electrical power to within 6 feet (2 m) of ice machine in accordance with local and national codes. Outdoor installation is not recommended and will void warranty. 2.1 Installation site requirements H_C1010 NEMA 6-15 ➊ ➋ H_D710 NEMA 5-15 ➌ H_C1410 NEMA 6-20 ➍ ➍ 3/4" barb x 3/4" FPT 3/4" MPT x 1" slip 2 ft.
3. Dispenser Top Preparation WARNING! §§ Prior to installing the louvered docking assembly, ensure that the drain fitting is oriented (right or left) correctly for your installation. An optional straight drain fitting is also supplied. You may need to remove the back panel of the docking assembly in order to re-orient or change the drain fitting. Replace back panel prior to mounting the docking assembly.
4. Mount Ice Machine Mounting options: Cabinet, Wall, Stand In cabinet Wall bracket Stand 22.00" (55.9 cm) 29.50" (74.9 cm) 25.50" (64.8 cm) 6.00" (15.24 cm) 28.70" (72.9 cm) 21.00" (53.3 cm) 4.1 Ice machine in cabinet Ice machines can be installed undercounter/in-cabinet to fill bins or dispensers using RIDE technology. Care must be taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice machine outages.
Front View Top View Access panel/ door on counter 2" (51 mm) ➌ ➊ 2.25" (57 mm) ➍ 2" (51 mm) 24" x 15" cutout (610 mm x 381 mm) bottom of ice machine side of ice machine CAUTION • Keep ventilation openings in the appliance enclosure clear of obstruction. Failure to do so could result in damage to equipment. • To ensure proper ventilation (if not using supplied grille) carefully review air circulation specifications on previous page (4.1) 3D Counter View 31.25" min. (794 mm) 23.5" min.
supplied grilles 18.00" (45.7 cm) min. ice transport tube Horizon ice machine minimum 1/4" per foot (2 cm per meter) pitch toward ice machine 24.50" (62.2 cm) min. secure to prevent dips and traps from forming electric exhaust 23.55" (59.9 cm) min. air in see dispenser specification sheet for installation requirements water drain cabinet door must mate directly to air intake gasket 12.00" (30.
5. External Connections 5.1 Transport tube installation ➋ ➍ Hot Water 160 F (71 C) ➏ ➎ ➐ ➑ ➊ ➌ ➒ ➓ 1/4" 1' Ice transport tube tips §§ Insulate entire length of ice transport tube ➊ §§ Secure ice transport tube ➋ as needed to prevent dips and traps from forming. For long tube runs see next page. §§ Pitch ice transport tube at least 1/4" per foot (6,4mm/0.
5.1.1 Long tube run recommendations max. 2 ft (.6m) ➋ §§ §§ §§ §§ §§ 1/4" ➊ 1' Pitch ice transport tube to allow melt water to drain towards ice machine ➊ Secure insulated ice transport tube at least every 2 ft (.6m) to prevent dips or traps ➋ Maximum length of transport tube is 75’ (22.5 m). Maximum rise is 20’ (7.5 m). Maximum length of transport tube for Micro Chewblet applications is 10’ (3 m).
5.2 Air-cooled ice machines only 5.3 Water-cooled ice machines only ➊ ➊ ➏ ➋ ➋ ➐ ➌ ➌ ➏ Minimum 8" radius 2 ft. x 1" OD silicone tubing 2 ft. x 1" OD silicone tubing 3/4" barb x 3/4" FPT 3/4" barb x 3/4" FPT ➍ ➍ 3/4" MPT x 1" slip 3/4" MPT x 1" slip ➎ 1" Stand pipe/Drain ➎ 1" Stand pipe/Drain §§ Rough-in ice machine potable water supply ➊. 3/8" push-in connection will be made at shut-off valve inside machine §§ Remove access panel if necessary ➋.
6. Internal Connections Air-cooled ice machines – follow steps 6.1 and 6.4. 6.1 Ice transport tube 6.2 Potable water lines ➋ ➊ ➊ §§ Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain fitting ➊. §§ Insert potable water line into valve ➊. §§ Insert ice transport tube all the way into coupling and tighten nut firmly ➋. 6.3 Power cord 6.4 Power cord §§ Remove twist tie. §§ Carefully pass cord thru opening and plug into wall outlet.
6.5 TDS switch CLEAN POWER ON LOW BIN MAKING ICE SLEEP CYCLE TIME DELAY LOW WATER MAINT/CLEAN SERVICE HIGH AMPS TDS HIGH LOW §§ Set the TDS switch on the electrical box: –– HIGH: for extended service life –– LOW: for low-scale water Water-cooled ice machines – follow steps 6.6 through 6.11. 6.6 Cooling Lines 6.7 Ice transport tube ➋ In Out ➊ §§ Install ice machine cooling water lines to louvered docking assembly.
6.8 Potable Water Line 6.9 Cooling lines and power ➋ ➊ ➊ §§ Insert potable water line into valve ➊. §§ Connect cooling water lines to ice machine ➊. (Water "Out" connects to water regulator.) §§ Water valve is set at the factory. DO NOT remove seal or adjust water valve ➋. 6.10 Power cord 6.11 §§ Remove twist tie. §§ Carefully pass cord thru opening and plug into wall outlet. §§ For H_E units, install a suitable plug.
6.
7. Front Cover Install front cover to ice machine. 7.1 Install cover - undercounter air-cooled application only 7.2 Install front cover ➊ ➋ ➋ ➌ ➌ NOTICE! §§ Keep ventilation openings in the appliance enclosure clear of obstruction. Failure to do so could result in damage to equipment. §§ To ensure proper ventilation (if not using supplied grille) carefully review air circulation specifications in section 4.
8. Dispenser Agitation Adjustment 8.1 Agitation adjustments - CORNELIUS 3.5 MOTOR ON TIME: SET TO 1 SECOND 4.5 5 E-BOARD AGITATOR TIMER 3 2.5 2 2 HRS MOTOR OFF TIME: SET TO 1 HOUR 4 1.5 1 ON TIME .5 2.5 HRS 3 HRS 30 MIN 10 MIN OFF TIME 1.5 HRS 1 HR Cornelius models ED, DB, DF, IDC and Flavor Fusion §§ Adjust the agitation tier located on the Cornelius PC board to 1 second on, 1 hour off. Note: See Cornelius manual or call Cornelius Technical Service at 1-800-238-3600 for more information.
8.3 Agitation adjustments – LANCER FS SERIES Initialization Screen (Boot Up Only) Lancer FS-16 Ver. 0.
8.
8.
9. RIDE model ice machine start up procedure The start-up procedure below is intended to ensure that ice machine is operating properly after installation has been made. Check each item listed and call factory immediately for assistance if you experience problems with unit. NOTICE! §§ Ice machine MUST be sanitized prior to operation! §§ Consult Operation and Service Manual provided with ice machine for sanitizing instructions. 9.1 Before turning on power 1. Sanitize ice bin. 2.
HARMONY • RIDE Technology Horizon Elite 710/1010/1410 23
Horizon, Horizon Elite, and Harmony are trademarks of Follett LLC. Follett, Chewblet and RIDE are registered trademarks of Follett LLC, registered in the US. 801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.