Installation Instructions
8
Horizon 710/1010/1410 BIN • TOP-MOUNT
4.2 Air-cooled ice machines only 4.3 Water-cooled ice machines only
➌
➊
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
➍
3/4" MPT x 1" slip
➎
➋
➏
➊
➏
➌
➋
➐
➑
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
➍
➎
§ Rough-in ice machine potable water supply ➊.
3/8" push-in connection will be made at shut-off
valve inside machine
§ Remove access panel if necessary ➋.
§ Connect the silicone tubing to the ice machine 3/4"
drain barb ➌.
§ Assemble the 3/4" barb x 3/4" FPT to the 3/4" MPT
x 1" slip. Connect the other end of the silicone
tubing to the 3/4" barb ➍.
§ Connect the 1" slip tting to the 1" stand pipe/drain
➎.
Note: Minimum 8" radius on silicone drain line.
Drain line from the ice machine must have
at least 1/4" per foot pitch (6,4mm/0,3m).
§ Apply Petrol-gel to barbed drain tting
➏
§ Replace access panel.
§ Rough-in ice machine potable water supply
➊.
3/8" push-in connection will be made at shut-off
valve inside machine
§ Remove access panel if necessary ➋.
§ Connect the silicone tubing to the ice machine
3/4" drain barb ➌.
§ Assemble the 3/4" barb x 3/4" FPT to the 3/4"
MPT x 1" slip. Connect the other end of the
silicone tubing to the 3/4" barb ➍.
§ Connect the 1" slip tting to the 1" stand pipe/
drain ➎.
Note: Minimum 8" radius on silicone drain
line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
§ Connect cooling water supply
➏ and return ➐
§ Apply Petrol-gel to barbed drain tting ➑
§ Replace access panel.