2. Site Preparation
Provide drainage, potable water supply and electrical power to within 6 feet (2m) of ice machine
in accordance with local and national codes. Outdoor installation is not recommended and will
void warranty.
2.1 Installation site requirements
➋
➌
➊
1/4"
1'
6-20
NEMA
H_C1410A/W
H_C1010A/W
6-15
NEMA
208 V –5% to 230 V +5%
1" Stand pipe/Drain
3/4" MPT x 1" slip
➍
3/4" barb x 3/4" FPT
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
➌
➍
5-15
NEMA
H_D710A
Electrical ➊
WARNING!
§ This appliance should be permanently connected by a qualied person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard.
H_C1010/1410(A/W)BT 208-230/60
Requires a 15A dedicated circuit.
HCD/HMD710ABT 115/60
Requires dedicated 15A circuit.
H_E1010/1410(A/W)HS 230/50
‡
(H_E1000A/W requires 15A circuit, 1.50 mm
2
wire)
H_E1400(A/W)HS 230/50/1-20 amps
‡
(H_E1400A/W requires 20A circuit, 4.00 mm
2
wire)
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable Water Supply ➋ (3/8" push-in internal connection, 3/8" OD tubing required)
10 psi to 70 psi (69 kpa to 483kpa) 45 F to 90 F (7 C to 32 C)
§ This equipment is to be installed with adequate backow protection to comply with applicable federal, state, and
local codes
Condenser water supply for water-cooled systems
➌ (1/4" FPT inlet, 1/4" FPT outlet)
10 psi min.; 150 psi max. (69 kpa min.; 1034 kpa max.)
20 F to 90 F (–7 C to 32 C)
1.5 gallons (5.68 liters) per minute
Drain
➍ (3/4" Barb)
Minimum 8” radius on silicone drain line. The drain line from the ice machine must have at least 1/4 in. per foot
(6,4 mm/0,3 m) pitch