Installation Guide

2 25FB425A/W, 50FB425A/W
CAUTION!
§ Do not tilt unit further than 30° off vertical during uncrating or installation.
§ Dispenser bin area contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If
access to this area is required, power to unit must be disconnected rst.
§ Follett recommends a Follett water lter system be installed in the ice machine inlet water line (standard capacity
#00130299, high capacity #00978957, carbonless high capacity #01050442).
§ Prior to operation clean the dispenser in accordance with instructions found in this manual.
§ Ice is slippery. Be sure counters and oors around dispenser are clean, dry and free of ice.
Specications
Electrical
§ Freestanding models (25FB425A/W, 50FB425A/W) require a dedicated circuit.
Total system Max. fuse
Basic electrical: 115 V/60 Hz/1 phase 11.0A 15A
§ Dispensers and RIDE ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug.
Connect to a dedicated 15A dedicated circuit.
Note: It is preferred that circuit be protected by a GFCI.
Model Electrical connection Circuits required
25FB425A/W, 50FB425A/W cord & plug provided 115/60/1, 20A max. fuse size
Ambient
Air temp 100 F/38 C Max. 50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp 90 F/32 C Max. 45 F/7.2 C Min. (Best performance below 70 F/21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.