Owners Manual

4 25FB425A/W, 50FB425A/W
Specications
Electrical
§ Freestanding models (25FB425A/W, 50FB425A/W) require a dedicated circuit.
Total system Max. fuse
Basic electrical: 115 V/60 Hz/1 phase 11.0A 15A
§ Dispensers and RIDE ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug.
Connect to a dedicated 15A dedicated circuit.
Note: It is preferred that circuit be protected by a GFCI.
Model Electrical connection Circuits required
25FB425A/W, 50FB425A/W cord & plug provided 115/60/1, 20A max. fuse size
Ambient
Air temp 100 F/38 C Max. 50 F/10 C Min. (Best performance below 80 F/27 C)
Water temp 90 F/32 C Max. 45 F/7.2 C Min. (Best performance below 70 F/21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
Plumbing
25/50 FB with ice machine in base
Dispenser drain 3/4" MPT
Ice machine drain 3/4" MPT
Dispenser water inlet 3/8" FPT
RIDE IM water inlet
Cond. inlet – w/c only 3/8" FPT
Cond. drain – w/c only 3/8" FPT
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§ 4" (10.2 cm) required at rear for freestanding models (25FB425A/W, 50FB425A/W).
Note: 12" (30.5 cm) at top advised for service.
Dry weight
§ 25/50 FB 212 lb (96 kg)